Skip to main content

Bosch PAM 220 Parts (3 60376 000)

Cover Plate
£2.45
Battery Case Cover
£2.05
Cover
£3.03
Cover
£3.03
Cover
£2.45
Slide Rail
£7.82

Bosch PAM 220 Spare Parts

The Bosch PAM 220 is a compact digital angle measuring device (type number often shown as 3603F76000) intended for tradespeople and DIYers who need quick, repeatable angle measurement and transfer. It features a 0°–220° measuring range with a typical angular accuracy of ±0.2° and an additional calculation accuracy of ±0.1°, a 400 mm leg length and two integrated spirit vials for coarse horizontal and vertical alignment. The unit runs from two LR6 (AA) 1.5 V batteries and displays measurements on an illuminated LCD with dedicated keys for Hold, MTR, COM and 180° supplementary angle functions.

Because the PAM 220 is a primarily electronic measuring instrument with moving legs and a mechanical hinge, the parts breakdown covers both small mechanical components (legs, hinge / sliding rail, scale, battery cover) and electronic sub-assemblies (display module, PCB and switches). Typical repair requirements we see include worn or damaged battery covers, a failing display or push-buttons, hinge wear or play affecting accuracy, and moisture or battery-leak damage to the PCB — all of which are reflected in the available Bosch PAM 220 parts.

PAM 220 parts diagram and parts list

The illustrated parts drawing for the PAM 220 uses drawing reference numbers to identify every visible component — leg assemblies, extension leg, battery compartment and small covers through to the display and keypad. Each drawing reference on the diagram corresponds to a Bosch part number in the parts list; examples that appear in the manufacturer breakdown include covers and small external components such as 1619PA7097 (closure/stop plate) and battery/facia covers like 1619PA7115. When using the diagram, match the drawing reference (the number beside the item in the illustration) to the parts list entry and the Bosch part number before ordering to ensure the correct item for your serial/type.

Battery compartment, covers and sliding rail

Simple service items are the most commonly required. The battery compartment cover and its locking tab are small plastic parts that are vulnerable to impact and wear — replacement covers are listed in the parts breakdown (for example 1619PA7115). The PAM 220 also uses a sliding rail/guide in the folding hinge area that can wear or bind; the sliding rail is shown separately in the parts list (for example 1619PA7119). Replacing worn rails or covers is a low-cost repair and restores mechanical alignment that is crucial for accurate angle transfer.

Display, keypad and electronics

The PAM 220’s measurement accuracy depends on a small LCD/display module, a control PCB and the keypad assembly. Symptoms such as a blank or intermittent display, frozen readings or unresponsive keys (Hold, MTR, COM, 180° and On/Off) usually point to battery problems, poor battery contacts or faults on the display/PCB. While some external elements — keypad buttons and button housings — are shown in the parts breakdown and available as spares, PCB-level repairs are best carried out by trained technicians because the electronics and sealed interfaces are specific to the model.

Hinge, legs and alignment vials

Mechanically, the PAM 220 consists of the folding leg, base leg and an optional leg extension. These mechanical assemblies are identifiable in the parts diagram and include the base and movable legs, the extension strip and the small locating parts that retain the legs in position. Wear at the hinge or damaged locating pins leads to loose leg movement and reduced transfer accuracy — in such cases replace the hinge/rail components listed in the breakdown. The two spirit vials for coarse alignment are also shown as separate items on the drawing and are replaceable where available.

Common faults and which parts to check

- Dim or blank display / intermittent readings: check and replace batteries (2 × LR6 (AA)), inspect battery contacts and the display/PCB assembly.
- Unresponsive or sticky buttons: inspect keypad housing and button seals; replace the button/cover parts identified in the parts list.
- Excessive play between legs or inaccurate transfer: inspect the hinge components and sliding rail; consider replacing worn rail (1619PA7119) or hinge sub-assemblies.
- Broken battery cover or damaged external covers: replace with the exact cover part (for example 1619PA7115, 1619PA7121, 1619PA7125 or 1619PA7139 depending on the drawing reference).

Finding the correct Bosch PAM 220 parts

Use the illustrated parts diagram and the associated parts list to match the drawing reference number to the manufacturer part number before ordering. Small components and covers often have several similar-looking part numbers — always confirm the PAM 220 type/serial (the type plate shows 3603F76000 on affected units) and the drawing reference from the diagram to avoid ordering the wrong variant. If your fault is electrical or the PCB appears damaged from moisture or battery leakage, ask us about professional repair options rather than attempting PCB replacement yourself — the PAM 220’s electronics are model-specific and not interchangeable with other Bosch measuring tools.